Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Braz. j. med. biol. res ; 54(3): e10428, 2021. tab, graf
Article in English | LILACS | ID: biblio-1153523

ABSTRACT

There is increasing evidence that neurofilament light chain (NF-L) can be considered as a biomarker for neuro-axonal damage. This polypeptide can be released into the cerebrospinal fluid (CSF) and the blood, where it can be quantified. The concentration of NF-L is elevated in patients with multiple sclerosis (MS) and psychiatric disorders. We aimed to investigate the NF-L levels in the CSF from treated MS patients and the relationship with depression or anxiety. The study involved three groups: control group (individuals without inflammation), the relapse-remitting multiple sclerosis (RRMS)-untreated group, and the RRMS-Fingo group (RRMS patients who were treated with fingolimod). MS disability was assessed by the Expanded Disability Status Scale, and depression and anxiety were evaluated by a neuropsychologist, using the Hospital Anxiety and Depression Scale, the Beck Depression Inventory-II, and the Beck Anxiety Inventory. Individual CSF samples were collected to measure NF-L levels. The results of the statistical analysis on levels of NF-L in the CSF of control subjects, RRMS-untreated patients, and RRMS-Fingo patients were significant. The relationship between depression and anxiety in RRMS-Fingo patients and NF-L levels was not statistically significant. In conclusion, MS events such as anxiety and depression appear to contribute to the onset of clinical relapses, subclinical cases, and neurodegeneration.


Subject(s)
Humans , Anxiety Disorders/etiology , Depression/etiology , Multiple Sclerosis/complications , Intermediate Filaments , Biomarkers , Neurofilament Proteins
2.
Arq. bras. med. vet. zootec. (Online) ; 70(1): 117-121, Jan.-Feb. 2018. tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-888081

ABSTRACT

São poucos os dados publicados sobre a aplicabilidade ou a confiabilidade dos métodos digitais para mensuração do ângulo do platô tibial (APT) em comparação à mensuração manual. O objetivo deste estudo foi comparar o APT obtido pelo cálculo manual padrão, em filmes radiográficos, com os valores obtidos por cálculos em imagens digitais, por meio do software do computador. Foram analisadas radiografias digitais do membro pélvico, direito e esquerdo, em perfil verdadeiro, de 20 cães saudáveis, com idade superior a um ano. Três observadores com graus de experiência semelhantes em cálculo do APT realizaram as mensurações em cada radiografia. Primeiramente, foram calculados os ângulos dos platôs tibiais manualmente nas películas radiográficas e, posteriormente, os cálculos foram realizados na imagem digital, por meio do software para medicina veterinária do sistema de raios X digital. Os resultados do presente estudo demonstraram diferenças significativas entre os métodos, com valor das médias do cálculo digital 20,48±3.71 e do cálculo manual 23.90±4.02. Valor de P foi < 0,01 na comparação entre médias dos dois grupos. Na avaliação interobservadores, houve diferença significativa no cálculo manual no perfil direito, o que sugere maior variação no cálculo manual quando comparado ao digital. O cálculo realizado pelo software apresentou menor variação nos valores interobservadores. Acredita-se que a menor variação obtida nos resultados aqui apresentados se dê em razão das facilidades proporcionadas pelo software. Conclui-se que houve diferença entre os valores obtidos por meio dos métodos convencional e digital no cálculo do ângulo do platô tibial, sendo os valores digitais menores entre os observadores, e que o método digital no cálculo do ângulo do platô tibial levou à menor variação quando comparado ao método manual.(AU)


There are few published data on the applicability and reliability of digital methods for measuring the TPA compared with manual measurement. The objective of this study was to compare the TPA obtained by calculating standard manual on conventional radiographs, with the values obtained by calculations in digital images through a computer program. Bilateral digital radiographs of hind limb were analyzed in true profile for 20 healthy dogs older than two years. Three observers with similar levels of experience in calculating the TPA conducted measurements on each radiograph. First we calculated the angle of the tibial plateaus manually in x-ray film and then the calculations were made through the program offered by the computer program in the digital image. The results of this study showed significant differences between the methods, with average value of 20.48±3.71 digital calculating average and 23.90±2.4 in the manual calculation. P value was < 0.01 when comparing averages. No significant difference in manual calculation in right profile were found between interobserver assessments, suggesting greater variation in manual calculation compared to digital. The calculation performed by the software showed less variation in values. The slight variation obtained in our results is believed to be due to the facilities provided by the software. There was a difference between the values obtained by means of conventional and digital methods for calculating the angle of the tibial plateau, and the smaller digital values between the observers and the digital method in the calculation of the tibial plateau angle led to less variation when compared to the manual method.(AU)


Subject(s)
Animals , Dogs , Comparative Study , Anterior Cruciate Ligament/abnormalities , Dogs/abnormalities , Knee/abnormalities
3.
Arq. bras. med. vet. zootec. (Online) ; 69(6): 1456-1460, nov.-dez. 2017. ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-910031

ABSTRACT

O objetivo deste trabalho foi demonstrar que o posicionamento radiográfico inadequado do membro pélvico de cães (imagens obliquadas) afeta a mensuração do ângulo do platô tibial (APT), levando à maior variação entre observadores. Foram realizadas duas projeções radiográficas nos membros pélvicos direito e esquerdo, uma em perfil verdadeiro e a outra com o membro obliquado em 21 cães provenientes do atendimento clínico cirúrgico do Hospital Veterinário da Universidade de Cuiabá, em Cuiabá-MT. Os critérios de inclusão foram cães livres de histórico ou afecção ortopédica nos membros pélvicos, pesando entre 15 e 40 quilos, sem predileção por raça ou sexo, entre dois e sete anos de idade. Foram obtidas 42 imagens radiográficas em perfil verdadeiro e 42 imagens radiográficas obliquadas. Três observadores com experiência em cálculo do APT fizeram as mensurações. Nos cálculos das imagens em perfil verdadeiro, o observador 1 obteve uma média de 23,35º ± 2,82; o observador 2, média de 23,88º ± 4,83; e o observador 3, média de 24,54º ± 4,01, não sendo encontrada diferença significativa entre o cálculo dos três avaliadores, P=0,944 (P > 0,05), nas imagens em perfil verdadeiro. Nos cálculos das imagens obliquadas, o observador 1 obteve uma média de 21,69º ± 4,22; o observador 2, média de 19,42º ± 5,92; e o observador 3, média de 22,64º ± 5,23, e foi encontrada diferença significativa entre o cálculo dos três observadores, P=0,016 (P < 0,05). Com esses dados, pôde-se demonstrar que a imagem radiográfica obliquada compromete o valor final do cálculo do ângulo do platô tibial em cães, levando à variação numérica estatisticamente significativa entre observadores. Conclui-se, assim, que um posicionamento correto do membro pélvico, em perfil verdadeiro, deve ser sempre utilizado para a obtenção de imagens, com o objetivo de mensurar o valor do APT.(AU)


This work aimed at demonstrating that an inadequate radiographic position of pelvic limbs of dogs, from a strict lateral radiographic view, resulted in oblique images, affecting the measurement of the tibial plateau angle (TPA). There were two radiographic projections of the right and the left pelvic limb, one in strict lateral radiographic view and another with inclined hind limb in 21 dogs from the clinical surgical assistance at Hospital Veterinário of Universidade de Cuiabá in Cuiabá-MT. Inclusion criteria were dogs free from pelvic hind limbs orthopedic affection records, weighing between 15 and 40 kilos, without a preference for breed or gender and ageing between two and seven years old. A total of 42 radiographic images in strict lateral radiographic view and 42 inclined limb radiographic views were obtained. Three observers with TPA calculation experience made measurements. In the calculus for the strict lateral radiographic view the first observer has reached an average of 23,35º ± 2,82, the second observer 23,88º ± 4,83 and the third observer 24,54º ± 4,01. No significant statistic differences among the calculus of the three evaluators p=0,944 (P>0,05) was found. In the calculus of the inclined limbs radiographic views the first observer reached an average of 21,69º ± 4,22, the second observer 19,42º ± 5,92 and the third observer 22,64º ±. 5,23. Significant statistic difference in the calculus of the three observers, p=0,016, that is to say, P<0,05 was found. The data indicated that the inclined limb radiographic image compromises the final value of the calculation of tibial plateau angle in dogs. Thus, correct positioning of the pelvic limb, in a strict lateral radiographic view, must be always used for obtaining images aiming at measuring the value of TPA.(AU)


Subject(s)
Animals , Dogs , Ligaments, Articular/diagnostic imaging , Patient Positioning/veterinary , Pelvis/diagnostic imaging , Tibia/anatomy & histology , Anterior Cruciate Ligament Injuries/veterinary , Osteotomy/veterinary
4.
Rev. argent. dermatol ; 96(3): 68-74, set. 2015. ilus
Article in Spanish | LILACS | ID: biblio-843054

ABSTRACT

La henna es un colorante vegetal ampliamente utilizado para crear tatuajes temporales. Su coloración negra se debe a la adición de parafenilendiamina, potente sensibilizador, conocido como agente causal de dermatitis de contacto por reacciones de hipersensibilidad tipo IV. La frecuencia de dermatitis de contacto secundarias a este compuesto parece ir en aumento, siendo necesario educar a la población en relación a los efectos secundarios a su uso, que en algunos casos pueden ser severos y permanentes.


Henna is a vegetal colorant widely used to create temporary tattoos. Its black color is created by the addition of paraphenylenediamine that is a potent sensitizer agent, known as a cause of type-IV allergic contact dermatitis. The frequency of contact dermatitis secondary to this compound appears to be increasing, being necessary to educate people regarding the secondary effects of its use, which in some cases can be severe and permanent.

5.
Braz. j. med. biol. res ; 44(10): 1013-1017, Oct. 2011. ilus
Article in English | LILACS | ID: lil-600688

ABSTRACT

An increased incidence of nosocomial and community-acquired infections caused by methicillin-resistant Staphylococcus aureus (MRSA) has been observed worldwide. The molecular characterization of MRSA has played an important role in demonstrating the existence of internationally disseminated clones. The use of molecular biology methods in the surveillance programs has enabled the tracking of MRSA spread within and among hospitals. These data are useful to alert nosocomial infection control programs about the potential introduction of these epidemic clones in their areas. Four MRSA blood culture isolates from patients hospitalized at two hospitals in the city of São Paulo, Brazil, were analyzed; one of them was community acquired. The isolates were characterized as SCCmec, mecA and PVL by PCR, pulsed-field gel electrophoresis (PFGE) profile and molecular sequence typing (MLST) genotyping. The isolates presented type IV SCCmec, and none proved to be positive for PVL. The isolates showed a PFGE profile similar to the pediatric clone. MLST genotyping demonstrated that the isolates belonged to clonal complex 5 (CC5), showing a new yqiL allele gene, resulting in a new sequence typing (ST) (1176). Our results showed that strains of MRSA carrying a new ST are emerging in community and nosocomial infections, including bacteremia, in São Paulo, Brazil.


Subject(s)
Humans , Cross Infection/microbiology , Methicillin-Resistant Staphylococcus aureus/genetics , Multilocus Sequence Typing/methods , Staphylococcal Infections/microbiology , Bacterial Typing Techniques , Brazil , Bacterial Proteins/genetics , Community-Acquired Infections/microbiology , Electrophoresis, Gel, Pulsed-Field , Genotype , Methicillin-Resistant Staphylococcus aureus/isolation & purification
6.
Braz. j. phys. ther. (Impr.) ; 13(1): 65-72, jan.-fev. 2009. graf, tab
Article in English, Portuguese | LILACS | ID: lil-508917

ABSTRACT

OBJETIVO: Comparar os efeitos de diferentes intervalos de recuperação (IR) entre séries de contração isocinética no desempenho muscular em idosos. MÉTODOS: Vinte idosos voluntários (66,9±3,9 anos, 76,1±13,4kg, 169±5,2cm) foram submetidos a três sessões de exercício resistido isocinético unilateral da musculatura extensora do joelho com diferentes IR (1 minuto, 2 minutos, e 3 minutos) na velocidade de 60°•s-1. Cada sessão consistia em três séries de 10 repetições durante as quais foram avaliados o pico de torque (PT), trabalho total (TT) e índice de fadiga (IF). ANOVA fatorial para medidas repetidas, com a análise de Post hoc por Bonferroni, foi utilizada para identificar possíveis diferenças entre os IR. O nível de significância estatístico utilizado foi de p<0,05. RESULTADOS: Não foram observadas diferenças no desempenho muscular entre as 1as séries nos diferentes IR (p>0,05). Apesar de ter sido observado menor desempenho muscular na 3ª série em todos os IR, maiores quedas no PT, TT e IF foram observadas quando adotado o IR de 1minuto (p<0,05). CONCLUSÃO: Os resultados mostraram que a variável IR exerce importante influência sobre o desempenho muscular isocinético em idosos, principalmente a partir da 3ª série, o que sugere incrementos no IR à medida que séries subsequentes forem executadas durante a mesma sessão de exercícios.


OBJECTIVE: To compare the effects of different rest intervals (RI) between sets of isokinetic contractions on muscle performance in older adults. METHODS: Twenty older participants (66.9±3.9 years; 76.1±13.4kg; 169±5.2cm) underwent three sessions of unilateral isokinetic training for the knee extensor muscles, with different RI (1 minute, 2 minutes and 3 minutes) at an angular velocity of 60°•s-1. Each session consisted of three sets of 10 repetitions, during which the peak torque (PT), total work (TW) and fatigue index (FI) were evaluated. Factorial ANOVA for repeated measurements, with Bonferroni post-hoc analysis, was used to identify possible differences between the RI. The statistical significance level was set at p<0.05. RESULTS: No differences in muscle performance during the first sets were observed between the different RI (p>0.05). Although muscle performance was lower during the third sets with all RI, the greatest decreases in PT, TW and FI occurred with the 1 minute RI (p<0.05). CONCLUSIONS: The results showed that the RI variable has an important influence on isokinetic muscle performance in older adults, particularly from the third sets onwards, which suggests that RI should be increased as successive sets are performed within the same exercise session.

7.
Arq. bras. med. vet. zootec ; 61(1): 149-155, fev. 2009. graf, tab
Article in English | LILACS | ID: lil-513036

ABSTRACT

Fifty-four samples were collected from growing and finishing pigs for the molecular diagnosis of enzootic porcine pneumonia. Nineteen lung fragments were obtained from pigs that showed signs of respiratory disease and 35 nasal swabs were obtained from clinically healthy pigs. For the detection of the bacterial genome in the samples, the nested PCR technique was used to amplify a fragment of 706bp. This fragment was subsequently cloned and sequenced. The sequence of obtained nucleotides was compared with six other sequences of Mycoplasma hyopneumoniae and 11 sequences of other bacteria available in the Genbank. To measure the sensitivity of the nested PCR, serial dilutions (10-1 to 10-15) of cloned fragments were conducted based on the concentration of 300ng. Ten lung fragments and eight nasal swabs showed positive for M. hyopneumoniae and the limit of detection was estimated to be 0.3fg DNA cloned. The sequence of nucleotides obtained showed 99.1 percent homology with the other sequences of M. hyopneumoniae, demonstrating that the nested PCR used in this study may provide an important diagnostic tool for the detection of this agent.


Foram coletadas 54 amostras de animais em fase de crescimento e terminação para o diagnóstico molecular da pneumonia enzoótica suína. Dezenove fragmentos de pulmão foram obtidos de suínos que apresentavam sinais de doença respiratória e 35 suabes nasais foram obtidas de suínos clinicamente saudáveis. Para a detecção do genoma bacteriano nas amostras, foi utilizada a técnica de nested PCR que originou um fragmento de 706pb, o qual foi, posteriormente, clonado e sequenciado. A sequência de nucleotídeos obtida foi comparada com outras seis sequências de Mycoplasma hyopneumoniae e 11 sequências de outras bactérias disponíveis no Genbank. Para medir a sensibilidade da nested PCR, foram realizadas diluições seriadas (10-1 a 10-15) do fragmento clonado, partindo da concentração de 300ng. Dez fragmentos de pulmões e oito suabes nasais apresentaram resultado positivo para M. hyopneumoniae e o limite de detecção foi estimado em 0,3fg de DNA clonado. A sequência de nucleotídeos obtida foi de 99.1 por cento de homologia com as outras sequências de M. hyopneumoniae, demonstrando que a nested PCR utilizada neste estudo pode ser uma importante ferramenta de diagnóstico para a detecção desse agente.


Subject(s)
Animals , Diagnosis , Lung , Mycoplasma hyopneumoniae , Nose , Pneumonia of Swine, Mycoplasmal , Polymerase Chain Reaction/methods , Swine
8.
Braz. j. microbiol ; 39(4): 631-635, Dec. 2008. ilus, tab
Article in English | LILACS | ID: lil-504299

ABSTRACT

In the last decades, coagulase-negative staphylococci (CoNS), especially Staphylococcus epidermidis have become an important cause of bloodstream infections. In addition, rates of methicillin-resistance among CoNS have increased substantially, leading to the use of glicopeptides for therapy. The objective of this study was to evaluate eleven consecutives clinically relevant cases of oxacillin-resistant CoNS bacteremia in a general hospital localized in São Paulo city, Brazil. Five different species were identified by different phenotypic methods, including S. epidermidis (5), S. haemolyticus (3), S. hominis (1), S. warneri (1) and S. cohnii subsp urealyticus (1). A variety of Pulsed Field Gel Electrophoresis profiles was observed by macrorestriction DNA analysis in S. epidermidis isolates, but two of three S. haemolyticus isolates presented the same profile. These data indicated the heterogeneity of the CoNS isolates, suggesting that horizontal dissemination of these microorganisms in the investigated hospital was not frequent. One S. epidermidis and one S. haemolyticus isolates were resistant to teicoplanin and susceptible to vancomycin. The selective pressure due to the use of teicoplanin in this hospital is relevant.


Staphylococcus coagulase negativos (SCoN), especialmente Staphylococcus epidermidis tem se tornado causa importante de infecções da corrente circulatória nas últimas décadas. Além disso, percentuais de resistência a meticilina entre os SCoN têm aumentado significativamente, levando ao uso de glicopeptídeos nestes pacientes. O objetivo deste estudo foi avaliar onze casos consecutivos de bacteremia clinicamente relevantes por SCoN oxacilina resistentes em um hospital localizado na cidade de São Paulo, Brasil. Cinco diferentes espécies foram identificadas por diferentes métodos fenotípicos, incluindo S. epidermidis (5), S. haemolyticus (3), S. hominis (1), S. warneri (1) e S. cohnii subsp urealyticus (1). Diferentes perfis eletroforéticos obtidos pela técnica de "Pulsed Field Gel Electrophoresis" foram observados na análise da macrorestrição do DNA nos isolados de S. epidermidis, mas dois dos três isolados de S. haemolyticus apresentaram o mesmo perfil. Esses dados indicam uma heterogeneidade nos isolados SCoN, sugerindo que a disseminação horizontal no hospital investigado não é freqüente. Um isolado de S. epidermidis e um de S. haemolyticus foram resistentes à teicoplanina e sensíveis à vancomicina. Observa-se a relevância da pressão seletiva pelo uso de teicoplanina nos pacientes deste hospital.


Subject(s)
Humans , Coagulase , Drug Resistance, Microbial , Electrolytes , Glycopeptides/analysis , Oxacillin , Staphylococcal Infections , Staphylococcus/pathogenicity , Critical Pathways , Methods , Patients , Methods
9.
Braz. j. med. biol. res ; 37(4): 511-521, Apr. 2004. graf
Article in English | LILACS | ID: lil-357102

ABSTRACT

A gravimetric method was evaluated as a simple, sensitive, reproducible, low-cost alternative to quantify the extent of brain infarct after occlusion of the medial cerebral artery in rats. In ether-anesthetized rats, the left medial cerebral artery was occluded for 1, 1.5 or 2 h by inserting a 4-0 nylon monofilament suture into the internal carotid artery. Twenty-four hours later, the brains were processed for histochemical triphenyltetrazolium chloride (TTC) staining and quantitation of the schemic infarct. In each TTC-stained brain section, the ischemic tissue was dissected with a scalpel and fixed in 10 percent formalin at 0ºC until its total mass could be estimated. The mass (mg) of the ischemic tissue was weighed on an analytical balance and compared to its volume (mm ), estimated either by plethysmometry using platinum electrodes or by computer-assisted image analysis. Infarct size as measured by the weighing method (mg), and reported as a percent ( percent) of the affected (left) hemisphere, correlated closely with volume (mm , also reported as percent) estimated by computerized image analysis (r = 0.88; P < 0.001; N = 10) or by plethysmography (r = 0.97-0.98; P < 0.0001; N = 41). This degree of correlation was maintained between different experimenters. The method was also sensitive for detecting the effect of different ischemia durations on infarct size (P < 0.005; N = 23), and the effect of drug treatments in reducing the extent of brain damage (P < 0.005; N = 24). The data suggest that, in addition to being simple and low cost, the weighing method is a reliable alternative for quantifying brain infarct in animal models of stroke.


Subject(s)
Animals , Male , Rats , Cerebral Infarction , Coloring Agents , Staining and Labeling , Tetrazolium Salts , Disease Models, Animal , Infarction, Middle Cerebral Artery , Organ Size , Plethysmography , Rats, Wistar , Reproducibility of Results , Sensitivity and Specificity , Severity of Illness Index , Staining and Labeling
10.
Bol. Oficina Sanit. Panam ; 94(2): 142-9, 1983.
Article in Spanish | LILACS | ID: lil-15018

ABSTRACT

Se presentan los resultados de un estudio sobre la prueba tubeculinica comparativa en bovinos, parte de un programa para aumentar y mejorar la produccion de leche en Rio Grande do Sul, Brasil


Subject(s)
Animals , Tuberculin Test , Tuberculosis, Bovine , Mycobacterium bovis
SELECTION OF CITATIONS